LT Company

by LT Company

Hotline +49 (0) 89 550 59 8611 +49 (0) 89 550 59 8611 LT

Back

LNB LINE series luminaires with trunk wiring

Description

Luminaire for indoor sales areas with linear fluorescent lamps used as the light source. Versions are available with an IP20 or IP23 rating as well as one, two, or three lamps. IP20 units can be supplied with an additional specular/asymmetrical reflector or specular/protective louver.

Overview / Models list
Overview

Features

Installation

Mounted on the ceiling surface or suspended. The control gear is installed inside the housing. LNB connecting brackets and plates (ordered separately) are used for in-line connection. The minimum required number of suspensions for an in-line arrangement is n = N + 1, where n is the number of suspensions, and N is the number of luminaires connected in-line.

Design

White powder-painted sheet steel housing. The luminaire is supplied without the optical part (except the IP23 rated model). The optical part is optional; louvers for LNB are supplied with a reflector.

Optical part

White or specular metal reflector (ordered separately).

Lamp Type

FL

Usage

  • Hypermarkets-/supermarkets

Features

  • I
  • IP20
  • IP23
  • IK02/0,2 J
  • Clm App4
  • +5 to +35

Models list

Decoding messages
Title Number of Lamps Power Capability Ballast Socle Lamp Type Length Width Article no.
LNB 236 HF housing /main line harness/ IP20 Planned date of elimination: 10.07.2018 2 72 W ECG G13 FL 1230 mm 200 mm 1293000100
LNB 258 HF housing /main line harness/ IP20 Planned date of elimination: 10.07.2018 2 116 W ECG G13 FL 1530 mm 200 mm 1293000230
LNB 258 HF /main line harness/ IP23 Planned date of elimination: 10.07.2018 2 116 W ECG G13 FL 1575 mm 200 mm 1293000200
Show archived models
LNB 249 HFR /through wiring/ IP23 Planned date of elimination: 31.12.2015 2 98 W ECG reg G5 FL 1520 mm 200 mm 1293000500
LNB 158 HF housing /main line harness/ IP20 Planned date of elimination: 31.12.2015 1 58 W ECG G13 FL 1530 mm 200 mm 1293000020
LNB.TP 258 HF housing /main line harness/ IP20 Planned date of elimination: 10.10.2017 2 116 W ECG G13 FL 1530 mm 200 mm 1293000420
LNB 158 housing /main line harness/ IP20 Planned date of elimination: 31.12.2015 1 58 W EmCG G13 FL 1530 mm 200 mm 1293000030
LNB 235 housing /main line harness/ IP20 Planned date of elimination: 31.07.2016 2 70 W ECG G5 FL 1480 mm 200 mm 1293000050
LNB 136 HF housing /main line harness/ IP20 Planned date of elimination: 31.12.2015 1 36 W ECG G13 FL 1230 mm 200 mm 1293000010
LNB 236 housing /main line harness/ IP20 Planned date of elimination: 01.03.2016 2 72 W EmCG G13 FL 1230 mm 200 mm 1293000130
LNB 249 housing /main line harness/ IP20 Planned date of elimination: 15.02.2017 2 98 W ECG G5 FL 1480 mm 200 mm 1293000160
LNB 258 HF /with mirror reflector, main line harness/ IP23 Planned date of elimination: 31.12.2015 2 116 W ECG G13 FL 1575 mm 200 mm 1293000210
LNB 258 HF ES1 housing /main line harness/ IP20 Planned date of elimination: 25.12.2016 2 116 W ECG G13 FL 1530 mm 200 mm 1293000220
LNB 358 HF housing /main line harness/ IP20 Planned date of elimination: 25.12.2016 3 174 W ECG G13 FL 1530 mm 250 mm 1293000280
LNB 358 housing /main line harness/ IP20 Planned date of elimination: 01.03.2016 3 174 W EmCG G13 FL 1530 mm 250 mm 1293000290
LNB 258 HF ES1 /main line harness/ IP23 Planned date of elimination: 10.07.2018 2 116 W ECG G13 FL 1575 mm 200 mm 1293000310
LNB 236 /w/o main line harness/ IP23 Planned date of elimination: 01.06.2015 2 72 W EmCG G13 FL None mm None mm 1293000360
LNB 236 HFD housing /main line harness/ IP20 Planned date of elimination: 01.06.2015 2 72 W ECG reg Dali G13 FL None mm None mm 1293000440
LNB 236 ES1 housing /main line harness/ IP20 Planned date of elimination: 01.06.2015 2 72 W EmCG G13 FL None mm None mm 1293000450
LNB.TP 258 HF ES1 housing /main line harness/ IP20 Planned date of elimination: 10.07.2017 2 116 W ECG G13 FL 1530 mm 200 mm 1293000460
LNB 249 /through wiring/ IP23 Planned date of elimination: 10.07.2017 2 98 W ECG G5 FL 1520 mm 200 mm 1293000480
LNB 258 /through wiring/ IP23 Planned date of elimination: 01.06.2015 2 116 W EmCG G13 FL None mm None mm 1293000490
LNB 228 /main line harness/ IP23 Planned date of elimination: 01.06.2015 2 56 W ECG G5 FL None mm None mm 1293000700
LNB 280 /main line harness/ IP23 Planned date of elimination: 31.07.2016 2 160 W ECG G5 FL 0 mm 0 mm 1293000540
LNB.TP 249 /through wiring/ IP23 Planned date of elimination: 31.07.2016 2 98 W ECG G5 FL 0 mm 0 mm 1293000590
LNB 258 HF ES1 housing /through wiring/ IP20 Planned date of elimination: 01.06.2015 2 116 W ECG G13 FL None mm None mm 1293000600
LNB 258 HF /through wiring/ IP23 Planned date of elimination: 10.07.2018 2 116 W ECG G13 FL 0 mm 0 mm 1293000650
LNB 258 HF ES1 /through wiring/ IP23 Planned date of elimination: 31.12.2015 2 116 W ECG G13 FL 0 mm 0 mm 1293000660
LNB 258 HFD housing /main line harness/ IP20 Planned date of elimination: 01.06.2015 2 116 W ECG reg Dali G13 FL None mm None mm 1293000670
Download